PR 3104-N Isolated converter

Original price was: $380.00.Current price is: $230.00.

PR 3104-N Signal Converter, brand new and unused, complete with original packaging, in perfect condition, fully functional, with all specifications included. Suitable for use in industrial automation, PLCs, and control systems.

secure payment

Description

Functional highlights

  • Galvanic separation of analog current and voltage signals.
  • A competitive choice in terms of both price and technology for galvanic isolation of all signal types to SCADA systems or PLC equipment.
  • High 3-port isolation provides surge suppression that protects the control system from transients and noise and eliminates ground loops.
  • All terminals are over-voltage protected, polarity protected, and short-circuit protected.
  • The device can be mounted in a safe area or in Zone 2 / Division 2 areas and is approved for marine applications.

Technical highlights

  • Flexible 24 VDC (±30%) supply via power rail or connectors.
  • Factory-calibrated measurement ranges.
  • Fast response time < 7 ms.
  • Excellent signal/noise ratio > 60 dB.
  • High galvanic isolation of 2.5 kVAC.
  • Inputs and outputs are floating and galvanically separated.
  • A green front LED indicates normal operation and malfunction.
  • Wide ambient temperature range: -25…+70°C.

Programming

  • Easy configuration via DIP switches.

Mounting / installation

  • The narrow 6.1 mm housing allows up to 163 units per meter.
  • Units can be mounted side by side, horizontally and vertically, without an air gap on a standard DIN rail, even at 70°C ambient temperature.
  • Units can be supplied separately or installed on the PR 9400 power rail.

    Environmental Conditions

    Operating temperature -25°C to +70°C
    Storage temperature -40°C to +85°C
    Calibration temperature 20…28°C
    Relative humidity < 95% RH (non-cond.)
    Protection degree IP20
    Installation in Pollution degree 2 & meas. / overvoltage cat. II

    Mechanical specifications

    Dimensions (HxWxD) 113 x 6.1 x 115 mm
    Weight approx. 70 g
    DIN rail type DIN EN 60715/35 mm
    Wire size 0.13…2.5 mm2 / AWG 26…12 stranded wire
    Screw terminal torque 0.5 Nm
    Vibration IEC 60068-2-6
    2…25 Hz ±1.6 mm
    25…100 Hz ±4 g

    Common specifications

    Supply

    Supply voltage 16.8…31.2 VDC
    Max. required power ≤ 1.2 W
    Max. power dissipation 0.55 W

    Isolation voltage

    Isolation voltage, test / working 2.5 kVAC / 300 VAC (reinforced)
    Zone 2 / Div. 2 250 VAC

    Response time

    Response time (0…90%, 100…10%) < 7 ms
    Programming DIP switches
    Signal / noise ratio > 60 dB
    Cut-off frequency (3 dB) > 100 Hz
    Signal dynamics, input Analog signal chain
    Signal dynamics, output Analog signal chain
    Accuracy Better than 0.05% of selected range
    Temperature coefficient < ±0.01% of span / °C
    EMC immunity influence < ±0.5% of span
    Extended EMC immunity: NAMUR NE21, A criterion, burst < ±1% of span

    Input specifications

    Current input

    Measurement range 0…23 mA
    Programmable measurement ranges 0…20 and 4…20 mA
    Input voltage drop < 1.5 VDC
    Input resistance Nom. 20 Ω + PTC 50 Ω
    2-wire transmitter supply > 17 V / 20 mA

    Voltage input

    Measurement range 0…10.25 V
    Functional range 0…11.5 V / 0…5.75 V
    Programmable measurement ranges 0/1…5 and 0/2…10 V
    Input resistance ≥ 500 kΩ

    Output specifications

    Current output

    Signal range 0…23 mA
    Programmable signal ranges 0 / 4…20 mA
    Load (@ current output) ≤ 600 Ω
    Load stability ≤ 0.002% of span / 100 Ω
    Current limit ≤ 28 mA

    Voltage output

    Signal range 0…10 VDC
    Programmable signal ranges 0/1…5 and 0/2…10 V
    Load (@ voltage output) ≥ 10 kΩ
    of span = of the DIP switch selected output range

    I.S. / Ex marking

    ATEX II 3 G Ex ec IIC T4 Gc
    IECEx Ex ec IIC T4 Gc
    FM, US Cl. I, Div. 2, Gp. A, B, C, D T4 or Cl. I, Zone 2, AEx nA IIC T4
    FM, CA Cl. I, Div. 2, Gp. A, B, C, D T4 or Cl. I, Zone 2, Ex nA IIC T4
    EAC Ex 2Ex nA IIC T4 Gc X

    Observed authority requirements

    EMC 2014/30/EU & UK SI 2016/1091
    LVD 2014/35/EU & UK SI 2016/1101
    ATEX 2014/34/EU & UK SI 2016/1107
    RoHS 2011/65/EU & UK SI 2012/3032
    EAC TR-CU 020/2011
    EAC Ex TR-CU 012/2011

    Approvals

    ATEX KEMA 10ATEX0147 X
    IECEx KEM 10.0068X
    UKEX DEKRA 21UKEX0055X
    c FM us FM17US0004X / FM17CA0003X
    c UL us, UL 61010-1 E314307
    CCC 2020322310003554
    EAC Ex EAEU KZ 7500361.01.01.08756
    DNV Marine TAA00001RW