Sale!

PR 4104 Universal uni-/bipolar signal transmitter

Original price was: $360.00.Current price is: $280.00.

  • Measures and outputs uni-/bipolar voltage and current signals
  • Works with both passive and active inputs and outputs
  • Uses the PR 4500 display series for programming and process monitoring
  • Fast < 20 ms response time and excellent < 0.05% accuracy
  • Universally powered by 21.6…253 VAC / 19.2…300 VDC
secure payment

Description

Application

  • Fast < 20 ms response time for measuring signals produced by torque, position, current & acceleration sensors.
  • User configurable bipolar or unipolar I/O means the 4104 is suitable for nearly any voltage or current conversion.
  • The excitation source enables measurement of two or three wire transmitters.
  • The active or passive I/O makes the 4104 perfect for power matching current loops.
  • Converts narrow bipolar inputs to wide bipolar or unipolar outputs, e.g., ±1 volt input = ±10 volt or 4…20 mA output.
  • Selectable direct or inverse I/O makes the 4104 suitable for proportional control applications.
  • The ”V-curve” function outputs 100% – 0 – 100% when a 0 – 100% input signal is present.

Technical characteristics

  • The latest analog and digital techniques are used to obtain maximum accuracy and immunity to interference.
  • The current output can drive up to 800 Ohms, with an adjustable response time of 0.0…60.0 seconds.
  • Exceptional mA output load stability of < 0.001% of span/100 Ohm.
  • Meets the NAMUR NE21 recommendations, ensuring high accuracy in harsh EMC environments.
  • Meets the NAMUR NE43 recommendations, allowing the control system to easily detect a sensor error.
  • Each unit is tested to a high 2.3 kVAC, 3-port galvanic isolation level.
  • Excellent signal to noise ratio of > 60 dB.

Mounting / installation / programming

  • Very low power consumption means units can be mounted side by side without an air gap – even at 60°C ambient temperature.
  • Approved for marine applications.
  • Configuration, monitoring, 2-point process calibration and more are accomplished using PR’s 4500 series of detachable displays.
  • All programming can be password protected.

    Environmental Conditions

    Operating temperature -20°C to +60°C
    Storage temperature -20°C to +85°C
    Calibration temperature 20…28°C
    Relative humidity < 95% RH (non-cond.)
    Protection degree IP20
    Installation in Pollution degree 2 & meas. / overvoltage cat. II

    Mechanical specifications

    Dimensions (HxWxD) 109 x 23.5 x 104 mm
    Weight approx. 155 g
    Weight incl. 4501 / 451x (approx.) 170 g / 185 g
    DIN rail type DIN EN 60715/35 mm
    Wire size 0.13…2.08 mm2 AWG 26…14 stranded wire
    Screw terminal torque 0.5 Nm
    Vibration IEC 60068-2-6
    2…13.2 Hz ±1 mm
    13.2…100 Hz ±0.7 g

    Common specifications

    Supply

    Supply voltage, universal 21.6…253 VAC, 50…60 Hz or 19.2…300 VDC
    Max. required power ≤ 2.5 W
    Max. power dissipation ≤ 2.5 W

    Isolation voltage

    Isolation voltage, test / working 2.3 kVAC / 250 VAC

    Response time

    Response time (0…90%, 100…10%) < 20 ms

    Auxiliary supplies

    2-wire loop supply > 16 V / 20 mA
    3-wire loop supply > 18 V / 20 mA
    Loop supply limitation 30 mA
    Programming PR 4500 communication interfaces
    Signal / noise ratio > 60 dB
    Cut-off frequency (3 dB) > 40 Hz
    Accuracy Better than 0.05% of selected range
    EMC immunity influence < ±0.5% of span
    Extended EMC immunity: NAMUR NE21, A criterion, burst < ±1% of span

    Input specifications

    Current input

    Signal range ±23 mA
    Programmable measurement ranges 0…20 and 4…20 mA ± 10 and ± 20 mA
    Input voltage drop 1.4 V @ 20 mA
    Loop error detection, 4…20 mA: Low < 3.6 mA
    Loop error detection, 4…20 mA: High > 21 mA

    Voltage input

    Signal range ±12 V
    Programmable measurement ranges 0/0.2…1, 0/1…5, 0/2…10 VDC ±1, ±5 and ±10 V
    Input resistance > 2 MΩ
    V-curve function, 100-0-100% 20-0-20 mA
    External loop supply 3.5 – 26 V

    Voltage output

    Programmable signal ranges 0/0.2…1; 0/1…5 ; 0/2…10 V ±1, ±5 and ±10 V
    Direct or Inverted action
    V-curve function, 100-0-100% 1-0-1, 5-0-5 and 10-0-10 V
    Load (@ voltage output) ≥ 500 kΩ
    Response time, programmable 0.0…60.0 s
    Output limitation – outside range: on unipolar V signals starting from 0 0 and 115% of max. value
    Output limitation – outside range: on unipolar V signals with offset -5% of min. value and 115% of max. value
    Output limitation – outside range: on bipolar V signals ±115% of min. & max. values
    Sensor error indication, at 4…20 mA input: selectable Low, High, Zero, None

    Observed authority requirements

    EMC 2014/30/EU & UK SI 2016/1091
    LVD 2014/35/EU & UK SI 2016/1101
    RoHS 2011/65/EU & UK SI 2012/3032
    EAC TR-CU 020/2011

    Approvals

    c UL us, UL 508 E248256
    FM 3025177
    DNV Marine TAA0000101