Description
-
Functional highlights
- Galvanic separation of analog current signals.
- A competitive choice in terms of both price and technology for galvanic isolation of all signal types to SCADA systems or PLC equipment.
- High 3-port isolation provides surge suppression that protects the control system from transients and noise and eliminates ground loops.
- All terminals are over-voltage protected, polarity protected, and short-circuit protected.
- The device can be mounted in Safe area or in Zone 2 / Division 2 areas and is approved for marine applications.
Technical highlights
- Flexible 24 VDC (±30%) supply via power rail or connectors.
- Factory-calibrated measurement ranges.
- Fast response time < 7 ms.
- Excellent signal / noise ratio > 60 dB.
- High galvanic isolation of 2.5 kVAC.
- Inputs and outputs are floating and galvanically separated.
- A green front LED indicates normal operation and malfunction.
- Wide ambient temperature range: -25…+70°C.
Mounting / installation
- The narrow 6.1 mm housing allows up to 163 units per meter.
- Units can be mounted side by side, horizontally and vertically, without an air gap on a standard DIN rail, even at 70°C ambient temperature.
- Units can be supplied separately or installed on the PR 9400 power rail.
Environmental Conditions
Operating temperature -25°C to +70°C Storage temperature -40°C to +85°C Calibration temperature 20…28°C Relative humidity < 95% RH (non-cond.) Protection degree IP20 Installation in Pollution degree 2 & meas. / overvoltage cat. II Mechanical specifications
Dimensions (HxWxD) 113 x 6.1 x 115 mm Weight approx. 70 g DIN rail type DIN EN 60715/35 mm Wire size 0.13…2.5 mm2 / AWG 26…12 stranded wire Screw terminal torque 0.5 Nm Vibration IEC 60068-2-6 2…25 Hz ±1.6 mm 25…100 Hz ±4 g Common specifications
Supply
Supply voltage 16.8…31.2 VDC Max. required power 0.65 W Max. power dissipation 0.60 W Isolation voltage
Isolation voltage, test / working 2.5 kVAC / 300 VAC (reinforced) Zone 2 / Div. 2 250 VAC Response time
Response time (0…90%, 100…10%) < 7 ms Signal / noise ratio > 60 dB Cut-off frequency (3 dB) > 100 Hz Signal dynamics, input Analog signal chain Signal dynamics, output Analog signal chain Accuracy Better than 0.05% Temperature coefficient < ±0.01% of span / °C EMC immunity influence < ±0.5% of span Extended EMC immunity: NAMUR NE21, a criterion, burst < ±1% of span Input specifications
Current input
Measurement range 0…23 mA Input voltage drop < 1.5 VDC Input resistance Nom. 20 Ω + PTC 50 Ω Output specifications
Current output
Signal range 0…23 mA Load (@ current output) ≤ 600 Ω Load stability ≤ 0.002% of span / 100 Ω Current limit ≤ 28 mA of span = 0…20 mA I.S. / Ex marking
ATEX II 3 G Ex ec IIC T4 Gc IECEx Ex ec IIC T4 Gc FM, US Cl. I, Div. 2, Gp. A, B, C, D T4 or Cl. I, Zone 2, AEx nA IIC T4 FM, CA Cl. I, Div. 2, Gp. A, B, C, D T4 or Cl. I, Zone 2, Ex nA IIC T4 EAC Ex 2Ex nA IIC T4 Gc X Observed authority requirements
EMC 2014/30/EU & UK SI 2016/1091 LVD 2014/35/EU & UK SI 2016/1101 ATEX 2014/34/EU & UK SI 2016/1107 RoHS 2011/65/EU & UK SI 2012/3032 EAC TR-CU 020/2011 EAC Ex TR-CU 012/2011 Approvals
ATEX KEMA 10ATEX0147 X IECEx KEM 10.0068X UKEX DEKRA 21UKEX0055X c FM us FM17US0004X / FM17CA0003X c UL us, UL 61010-1 E314307 CCC 2020322310003554 EAC Ex EAEU KZ 7500361.01.01.08756 DNV Marine TAA00001RW